INNOCIGS EVIC PRIMO MINI – ERROR MESSAGES & PROTECTIONS
Recharge battery
If the voltage falls below 3.3 V, „BATTERY LOW" appears on the display. When the fire button is pressed again,
„BATTERY LOW LOCK" appears and the unit switches off. Please recharge the device.
Low Atomizer Protection
If the resistance of the coil is lower than 0.1 ohm in VW mode or 0.05 ohm in TC or TCR mode, the display shows
"ATOMIZER LOW".
Temperature Protection
If the temperature of the atomizer coil is above the temperature you set, the device will display " PROTECT". You
can continue to use the device normally.
Device too hot
When the temperature of the device becomes too hot, the power turns off and the display will read "DEVICE TOO
HOT". You will be able to use the device once it has cooled down.
69