Herunterladen Inhalt Inhalt Diese Seite drucken

X4-Life Inspector III Bedienungsanleitung Seite 19

Vorschau ausblenden Andere Handbücher für Inspector III:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Funktions
To switch through the different values in the display press
FUNCTION.
LCD-window 1 shows the elapsed time in which the attached
device has been using electricity. First, the two digits on the right
show seconds and the ones on the left show minutes. After 60
minutes, the digits on the right display minutes and the digits on
the left now show hours. After 24 hours the display starts again
at zero and the day display is increased by one.
Note: The measurement may have a deviation of +/- 2%.
Please note that the time recording will only start at approxima-
tely 0,1 watts usage by the attached device.
Mode 1) Time/Consumption/Cost
Window 2: Shows the wattage currently used.
Window 3: The total cost of the electricity used (COST).
Mode 2) Time/Electricity Used/Days
Window 2: The total use in kilowatt hours (KWh).
Window 3: How many days the attached device has been connec-
ted and has been using power (DAY).
Mode 3) Time/Voltage/Frequency
Window 2: The current voltage (V).
Window 3: The current frequency in hertz (Hz).
Mode 4) Time /Ampere/Power Factor
Window 2: The actual power consumption in ampere (A).
Window 3: The current power factor (POWER FACTOR). The
factor value can range from 0.00 to 1.00 and is equivalent to the
cos φ.

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für X4-Life Inspector III

Diese Anleitung auch für:

700379

Inhaltsverzeichnis