4. Installation Queen Pearl for integrated fitting
Installation must be carried out by a qualified fitter.
C
E
A
B
Installation of Queen Pearl for integrated fitting
6.
7.
8.
9.
10. Fit the drip tray and the tap bosses.
Drain
valve
11.
Water IN
D
12. Connect the plug to an earthed 230V 10A
13. Flush out approx. 2.5 litres of chilled still water
Connect the water hose from carbonated water
on the cooling unit to carbonated water on the tap
pillar. Then connect the water hose from cold water
on the cooling unit to cold water on the tap pillar.
Mount the gas dome (A) on the carbon dioxide
cylinder (B) and then fit the supplied nipple on
the gas dome. Connect the carbon dioxide
cylinder to cooling unit inlet CO2 using the hose (C).
Fit the water filter (D) and connect the filter to the
water cooling unit inlet using the hose (E).
Connect the supplied 1/2" hose to the water filter
and then to the water main. It is recommended that
you connect the hose to a shut-off tap.
Check that no kinks or sharp bends have formed
on the hoses during connection.
See page 9.
IMPORTANT! Fill with water
Before starting the cooling unit, it must be filled
with water. Lift the cooling unit cover and fill
the cooling tank with tap water until water runs out
from the drain valve.
wall socket.
and then approx. 2.5 litres of carbonated water
before putting the machine into use.