Herunterladen Inhalt Inhalt Diese Seite drucken

Location; Installation; Electrical Connections - Hoshizaki FM-150KE Installationsanleitung

Eisbereiter mit eingebautem vorratsbehälter
Vorschau ausblenden Andere Handbücher für FM-150KE:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13

4. LOCATION

This icemaker is not intended for outdoor use.
The icemaker should not be located next to ovens, grills or other high heat producing equipment.
This appliance is not suitable for installation in an area where a water jet could be used.
The location should provide a firm and level foundation for the icemaker.
Do not place anything on top of the icemaker or in front of the louver.
Normal operating ambient temperature should be within 5°C to 40°C. Water connection is cold water only. Operation of the
icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
Allow the clearance specified below for proper air circulation and ease of maintenance and/or service should they be required.
Top View
Left
15cm
In some high humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where
the floor can be affected by water.

5. INSTALLATION

Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held
responsible.
1) Position the icemaker in the selected permanent site.
2) Level the icemaker in both the left-to-right and front-to-rear directions by adjusting the legs.

6. ELECTRICAL CONNECTIONS

This icemaker requires an earth that meets the national and local electrical code requirements.
To prevent possible severe electrical shock to individuals or extensive damage to the unit, install a proper earth wire to the icemaker.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 13A supply. The electrical supply must be protected by a suitable circuit
breaker.
* Usually an electrical permit and services of a licensed electrician are required.
* If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres.
WARNING
CAUTION
NOTICE
IMPORTANT
Rear
15cm
Right
15cm
ICEMAKER
Front
CAUTION
WARNING
THIS APPLIANCE MUST BE EARTHED
Side View