SUPERIOR SLAVE
Modul der Regulierung Slave SUPERIOR
0-10
0-10
24VAC
VDC
GND
VDC
GND
1
2
2
GND
24V
GND
GND
23 24
25 26
25 26
1
2
1
2
24VAC
0-10V
0-10V
24VAC
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
POWER SUPPLY
Vanne/ Groupe Exterieur DX
Vanne/ Groupe Exterieur DX
Alimentation
UNIT DX
UNIT DX
MIX POINT
vanne
HEATER/
VENT-INT
HEATER/
VENT-EXT
24VAC
PREHEATER
PREHEATER
24VAC
24VAC
24VAC
24VAC
REC/BYP
POSTHEATER
REC/BYP
RPM
RPM
~
~
~
~
COOL/PUMP
~
~
~
~
~
GND
COOL/PUMP
PWM
GND
GND
PWM
GND
1
2
1
2
0-10V
GND
GND
1
+SSR -SSR
1
2
0-10V GND
(TC)
1
2
0-10V
(TC)
0-10V GND
0-10V
GND
0-10V
GND
15
16 17 18 19 20 21 22 23 24
25 26 27 28 29
30
31
32
25 26 27 28 29
30
31
32
FUSE
FUSE
(VENT-EXT)
(VENT-INT)
FUSE
FUSE
(PCB)
(PERIPHERY)
82
81 80 79 78 77 76 75 74 73
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
LO
L
LO
L
LO
N
N
L
ALARM
RUN
COOL/HEAT
ALARM
ALARM
RUN
COOL/HEAT
ERROR
DEFROST EXTERNAL
ERROR
230VAC
230VAC
230VAC
230VAC
HEATER
OUTPUT
HEAT PUMP
HEATER
OUTPUT
HEAT PUMP
HEAT PUMP
HEAT PUMP
PIR
FLAP-INT
FLAP-EXT
W. PUMP
230VAC
EXTERNAL
EXTERNAL
CONTACT
WATER
POMPE
CONTROL
CONTROL
EXTERNE
PUMP CONTROL
DE CIRCULATION
OUTPUT
OUTPUT
72 71
72 71
77 78
76 75
63 64
6
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
7
DX = ON/OFF
7
5
OUTLET
(Sortie pour unité
(Sortie pour unité
(Output for outdoor unit)
Registre
Commande
Commande
exterieure)
exterieure)
exterieure)
Air Rejeté
á distance
á distance
6
68 67
68 67
70 69
66 65
VCST4-AGSU1-S-EC-
2
1
0-10
VDC
GND
2
24
23
22
25 26
49 50
49 50
EXT. SENSOR
2
EXT. SENSOR
3
Capteur Externe.
3
Capteur Externe.
0-10V
(two-wire shielded cable)
MIX. POINT / OUTDOOR
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
Vanne/ Groupe Exterieur DX
UNIT DX
HEATER/
POSTHEATER
PREHEATER
24VAC
POSTHEATER
REC/BYP
T-EXT-1
T-EXT-2
T-EXT-3
T-INT-1
T-INT-2
~
COOL/PUMP
T-EXT-1
T-EXT-2
~
T-EXT-3
~
T-INT-1
T-INT-2
+SSR -SSR
+SSR -SSR
2
1
2
0-10V
GND
0-10V GND
9
0-10V
GND
33
25 26 27 28 29
34
35 36 37 38 39 40 41 42 43
30
31
32
33
34
33
34
35 36 37 38 39 40 41 42 43
SWO
SWO
DATA
DATA
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
70 69
PRESENCE
PRESENCE
RUN
COOL/HEAT
DEFROST EXTERNAL
REC ERR
DEFROST EXTERNAL
REC ERR
ERROR
FIRE
BOOST
FIRE
BOOST
SENSOR
SENSOR
OUTPUT
HEAT PUMP
ON/OFF
HEAT PUMP
ON/OFF
PIR
PIR
CONTACT
EXTERNAL
CONTACT
CONTACT
CONTACT
FIRE
FIRE
EXTERNE
CONTROL
EXTERNE
OUTPUT
INCENDIE
INCENDIE
BOOST
ON/OFF
BOOST
ON/OFF
ON/OFF
72 71
3
4
5 6
7
8
62 61
63 64
62 61
63 64
57 58
57 58
4
5
6
BOOST
BOOST
7
11
12
11
13
11
12
13
Commande
CMSI
CMSI
á distance
2VV. Creating innovative solutions for you and your business since 1995.
68 67
66 65
66 65
EF
VCST4-AGSU1-S-EC-
3
ou
ou
or
Control panel
or
Control panel
boitier de commande
boitier de commande
boitier de commande
ModBUS RTU via
ModBUS RTU via
20
19
49 50
EXT. SENSOR
3
Capteur Externe.
(two-wire shielded cable)
Câble deux fils blindé
J1/J2
J1/J2
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
T-EXT-1
T-EXT-2
T-EXT-3
T-INT-1
T-INT-2
-OUT
-OUT
-IN
-IN
-OUT
FILTER
FILTER
9
9
10
10
JP1
JP1
INT
INT
LED1
LED1
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
44 45 46 47 48 49 50
44 45 46 47 48 49 50
SWO
DATA
1
2
1
1
2
PRESENCE
IN GND
IN GND
REC ERR
FIRE
BOOST
15VAC
15VAC
15VAC
SENSOR
CO2/RH/EXT
CO2/RH/EXT
ON/OFF
CO2/RH/EXT
PIR
CONTACT
FIRE
CONTACT
CONTACT
ERROR
ERROR
INCENDIE
CONTACT
ERREUR
CONTACT
ERREUR
BOOST
9
10
11
62 61
59 60
59 60
57 58
7
BOOST
!
!
14
12
14
13
CMSI
SO
VCST4-AGSU1-S-EC-
in control module
GTC
GTC
GTC
ou
or
Control panel
ModBUS RTU via
Rs485
Rs485
Rs485
1
Wasserausgangssensor (Im Lieferumfang enthalten)
2
Signal zur SLAVE
3
Frostschutzfühler (NC)
4
Externe Steuerung - AN/AUS
5
J1/J2
Raumthermostat (Eingang)
6
Türkontakt (Eingang)
7
Signal aus der MASTER
8
Wasserventil (0-10V)
-IN
9
Slave-Adressen
FILTER
9
10
JP1
INT
LED1
9
SLAVE
2
IN GND
1
1
2
2
3
3
CONTACT
ERROR
4
4
CONTACT
ERREUR
5
5
59 60
!
14
VF
in Steuermodul
24V
GND
0-10V
24V
GND
HEAT
8
0-10V
SLAVE
6
6
7
7
8
8
9
9
10
A

Werbung

Inhaltsverzeichnis