If necessary, Bullerjan
hot
4
®
air stoves of construction
type I (type 00 and 01 with a
self-closing door – corres-
ponding torsion spring is
available as equipment)
can be connected to a joint
chimney.
Table No. 2 Triple of values for the calculation of chimney designs according to
EN 13384
Type Bullerjan
®
Rated thermal output (RTO)
Waste gas mass flow rate relating to RTO
Mean/Max. waste gas temperature
Delivery pressure
Delivery pressure at 0,8 x RTO
CO
2
Efficiency
3.5 Chimneys
Bullerjan
hot air stoves will need a chimney of their own
®
purpose of fire protection, the design of the chimney will be made
according to the EN 13384 using the triple of values indicated in
Table No. 2.
The safe operation and the rated thermal output of our Bullerjan
hot air stoves can only be guaranteed if the design of the chimney
with regard to fire protection has been proven to be calculated
according to the EN 13384 and confirmed by an authorised local
chimney sweep.
Unit
00
kW
6
g/s
9,2
°C
262/325
304/354
mbar
0,10
mbar
0,08
%
6,5
%
70,3
. For the
4
®
01
02
11
14
17,3
14,5
335/377
0,11
0,11
0,09
0,09
6,7
9,1
70,5
70,6