7.3 Charging controller info LED
Yellow LED: Not charging (standby)
Flashing LED: Charging
Green LED: Charging complete
Red LED: Error
8 Troubleshooting
Error message
Error
Overtemperature
(charging controller)
Overcurrent
Residual current (RCD)
Residual current
self-test
Undervoltage
Overvoltage
Defective charging
controller.
Mains plug overheated
No earth contact
8.1 Other issues
The pins do not lock into place:
When inserting the cable, apply plenty of pressure until the pins are properly connected to the
electric vehicle.
The vehicle is unlocked:
To start the charging process, the vehicle must be locked and switched off.
May vary depending on your vehicle.
9 Cleaning and care
Important:
– Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solu-
tions. These may damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply and the vehicle.
2. Clean the product and the cable with a damp, lint-free cloth.
Solution
Wait until the device has cooled down and
try again.
Disconnect the charging cable from the
vehicle and then reconnect it. Try restarting
the charging process.
Disconnect the charging cable from the
vehicle and then reconnect it. Try restarting
the charging process.
Disconnect the charging cable from the
vehicle and then reconnect it. Try restarting
the charging process. If the error persists,
discontinue use and contact customer
service.
Wait a moment and then try to restart the
charging process.
Wait a moment and then try to restart the
charging process.
Discontinue use and contact customer
service.
Wait until the device has cooled down and try
again. Disconnect the cable from the vehicle
and the power supply and let it cool down.
Ask an electrician to check the socket (230
V). Use another suitable mains socket.
10 Disposal
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should be disposed of separately
from unsorted municipal waste at the end of its service life.
All owners of waste equipment are obliged to dispose of waste equipment separa-
tely from unsorted municipal waste. Before handing the old device to a collection
point, end users are required to separate old batteries which are not enclosed by
the old device, as well as lamps which can be removed from the old device without
any damage.
Distributors of electrical and electronic equipment are legally required to accept waste equip-
ment free of charge. Conrad provides the following return options free of charge (more details
on our website):
At our Conrad stores

At the collection points established by Conrad

At the collection points of public waste disposal agencies or at the collection systems set up

by manufacturers and distributors in accordance with the German Electrical and Electronic
Equipment Act.
The end user is responsible for deleting personal data on the old device before disposal.
Please note that in countries outside Germany, other obligations may apply to the return and
recycling of old devices.
11 Technical data
11.1 Power supply
Nominal voltage ........................................ Max. 250 V/AC, 50 Hz
11.2 Connected load/current
Connected load/current ............................ max. 3.68 kW, 16 A
Charging current ....................................... 8 / 10 / 13 / 16 A
Number of phases .................................... 1
11.3 Charging cable
Cable length (total) ................................... 5 m
Cable length
(Type 2 connector to charging controller) ... 4.3 m
Cable length
(mains plug to charging controller) ........... 0.7 m
Charging standard (connector) ................. Type 2
Charging standard .................................... Mode 3
Insulation resistance ................................. > 1000 MOhm (DC 500 V)
Terminal temperature rise ......................... < 50 K
Withstand voltage ..................................... 2000 V
Mechanical lifespan .................................. > 10,000x plug in/out when idle
Shock resistance ...................................... Falls from a height of 1 m; compression by
..................................................................
Housing .................................................... PC, flame retardant according to UL94 V-0
Cable material .......................................... TPU
Contacts ................................................... Copper alloy, silver-plated
Protection rating (controller) ..................... IP65
Protection rating (Type 2 connector) ........ IP55
Certification ............................................... CE
Certification standard ................................ IEC 62196-1 / IEC 62196-2
EV connector ............................................ IEC 62196 Type 2
11.4 Miscellaneous
Dimensions (L x W x H) ............................ 5400 x 100 x 60 mm
Weight ...................................................... 2320 g
11.5 Ambient conditions
Operating conditions ................................. -25 to +45 °C, max. 95% RH (non-condensing)
Storage conditions .................................... -25 to +45 °C, max. 95% RH (non-condensing)
Maximum operating altitude ..................... < 2000 m
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
vehicles with a max. weight of 2 t.
*2632376_V2_0223_02_m_VTP_EN

Werbung

loading

Diese Anleitung auch für:

2632376