PERIODICAL MAINTENANCE

Any further adjustments on the refrigerator necessarily require the electric plug to be removed.
Check periodically the supply cable in order to detect any damage.
If the power supply cable is damaged, don't use the equipment and don't try to repair it: to prevent any
risk, it must be replaced by the manufacturer, by a member of the after-sales service staff, or anyway
by a person having similar qualifications.
In any case, none of the protective elements (the grill, the carter) must be removed by non qualified staff.
Absolutely avoid using the refrigerator without such protection.
The replacement of led lamps must be carried out only by an Authorized Service Center.
The lamps have to be replaced by identical lamps only.
OUTER CLEANING
For a good preservation of the cabinet's body a periodical cleaning is necessary.
EXTERNAL BODY: When necessary, the external body should be cleaned with a cloth and a neutral
soap and water solution.
STAINLESS STEEL SURFACES: Wash with warm water and mild detergent, rinse well and dry
with soft cloth. Avoid scouring pads etc. which will spoil the finish of the stainless steel.
SURFACES IN PLASTIC MATERIAL: Wash with warm water and mild detergent, rinse well and
dry with soft cloth; under no circumstances should alcohol, methylated spirits or solvents be used.
GLASS SURFACES: Only use products specifically designed for glass cleaning; It is not advisable
to use ordinary water which can leave a film of calcium on the surface of the glass.
DEFROSTING AND TANKS CLEANING
Theese units make an automatic defrosting in the displayng tank.
The storage compartment should be defrosted when frost on the walls has a thickness of more than
5 mm.
We recommend to make the defrosting of storage compartment and, at the same time, the cleaning of
displayng tank; proceed as follows:
1) Place the goods in special refrigerated containers, kept at the same temperature
2) Unplug the unit
3) Before cleaning the inside temperature must be equal to the ambient temperature; place a container
of warm but not boiling water inside the storage compartment, standing on a piece of cardboard,
and leave the door closed for about 30 min.
4) Clean the tanks walls with water and neutral soap, rinse and dry carefully.
5) Clean the tank, rinse and dry carefully.
6) Plug the unit and wait till the appliance reaches the right temperature before filling it again.
Warning! Do not use water jets for cleaning: this can damage the electrical
parts.
Warning! Do not use mechanical appliances or other means to speed up the
defrosting process, other than those recommended by the manufacturer.
SEASONAL USE
When the unit is kept unused for a long time, please take note of the following procedures:
Unplug the unit;
Clean and dry well the tank;
Leave the covers half open to prevent bad smells forming;
Cover the unit with a curtain, place it in a dry room and sheltered from the atmospheric agents.