9. INITIAL ACTIVATION
€ Ensure the installation is completely connected. Mount all components.
€ In turn, check a-, b- and P-conductor against each other for short circuits.
€ Switch on the mains voltage.
• The ExtU address must be set at the main external unit.
• This is carried out using the service unit 10-870 or the Niko Configuration SW. If the ExtU address is not fixed, identical addresses will be formed in the
main external unit's and one external unit's secondary installation. This will cause a poor quality speech connection to both external units, as well as a
whistling sound.
• Set the value of the ExtU address between 50 and 63. When connecting several main external units to one 10-803, their ExtU addresses must be set
differently.
ATTENTION! Please note: a speech connection can only be established with a main external unit by a secondary installation when the main
external unit in question has previously sent a door call.
The connection between the 10-803 and the secondary installations runs via the lines 1, 2, 3, 4. The line is always connected in parallel with the bus on an
external unit of the secondary installation. If call is made at the main external unit, this is carried to all lines. The secondary installation confirming the ring signal,
is connected with the main external unit. Ring signals from the secondary installations are ignored by the 10-803. The connection is always established from
the main external unit to the secondary installation.
10. CONFIGURATION

10.1. Factory settings

The device is equipped with an EEPROM, in which the following default settings are saved:
Operating mode
10.2. Preset time
Factory setting door opener time
11. SETTINGS

11.1. Changing the operating mode

Switching from operating mode SECONDARY to MASTER or from MASTER to SECONDARY follows the same procedure. The steps are the following:
LED for the operating mode (yellow):
switches ON and OFF
(MASTER) / (SECONDARY)
Hold down programming ...
EN
MASTER
3 s, fixed setting
After approx. 3 s: LED, (yellow): flashing
...
After approx. 3 s:
LED for the operating mode (yellow):
switches OFF and ON
(SECONDARY) / (MASTER)
... then release