INSTRUCTION MANUAL
SMART RETROFIT KIT
Assembly (continued)
1. Open dispenser with key.
Then raise the hood, and swivel it for-
wards.
3. Carefully remove dummy plugs with a
flat head screwdriver.
Dummy plugs
22
UDU 5 M
2. Remove dispenser bottle from
dispenser.
4. Click electronics box into dispenser.
(1)
(2) CLICK
(2) CLICK
5. Secure cable guide to housing wall with
two M3 nuts (1).
Make sure that switch is located behind
operating lever of dispenser (2).
(2)
(1)
(1)
7. Bond cable retainer in dispenser housing
as per diagram.
6. Secure fill level sensor to backwall of dis-
penser (1). Bend both side tabs inwards
to do this (2).
(2)
(1)
45°
8. Fit battery box in holder via electronics
box.
(2)