PMO 0450
100 N
PMO 0900
100 N
PMO 1800
200 N
PMO 3600
200 N
PMO 7200
200 N
12. ATEX explosion protection
Due to the planned use of the radial piston motors and gearboxes in potentially explosive
areas, the following EU directive is decisive:
12.1. European directives, laws and regulations
2006/42/EG: European Machinery Directive
2014/34/EU: European Explosion Protection Directive
12.2. License plate according to directive 2014/34/EU
The identifier of the non-electrical equipment reads:
12.3. Explosion protection regulations
A number of regulations must be observed by the operator for equipment in potentially
explosive areas. The following list provides an overview of the essential regulations.
Within the European Union apply:
•
Directive 1999/92/EC on the minimum requirements to improve health protection
and
•
the safety of workers who may be endangered by explosive atmospheres.
•
EN50014
Electrical equipment for potentially explosive atmospheres - general provisions
•
EN60079-14 (IEC60079-14)
Electrical equipment for explosive gas atmospheres - Part 14: Electrical systems in
explosive atmospheres
•
EN60079-10 (IEC60079-10)
Electrical equipment for gas-explosive areas - Part 10: Classification of potentially
explosive areas
750 N
400 N
750 N
400 N
1500 N
800 N
1500 N
800 N
1500 N
800 N
II 2 D Ex h IIIC T100°C Db X
5 Nm
1.10 kg
5 Nm
1.30 kg
10 Nm
3.40 kg
10 Nm
4.00 kg
10 Nm
6.40 kg
II 2 G Ex h IIC T5 Gb X
2.00 kg
2.80 kg
2.20 kg
3.00 kg
6.10 kg
7.90 kg
6.70 kg
8.50 kg
9.10 kg
10.90 kg
2.10 kg
2.30 kg
5.90 kg
6.50 kg
8.90 kg
47