tool will do the job better and safer at the rate for
which it was designed.
b) Do not use the power tool if the switch does not
turn it on and off. Any power tool that cannot be
controlled with
the switch is dangerous and must be repaired.
c) Disconnect the plug from the powersource
and/or the battery pack from the power tool before
making any adjustments, changing accessories,
or storing power tools. Such preventive safety
measures reduce the risk of starting the power
tool accidentally.
d) Store idle power tools out the reach of children
and do not allow persons unfamiliar with the
power tool or these
instructions to operate the power tool. Power tools
are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment
or binding of moving parts, breakage of parts and
any other condition that may affect the power
tools operation. If damaged, have the power tool
repaired before use. Many accidents are caused
by poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly
maintained cutting tools with sharp cutting edges
are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits
etc. in accordance with these instructions, taking
into account the working conditions and the
work to be performed. Use of the power tool for
operations different from those intended could
result in a hazardous situation.
5) Battery tool use and care
a) Recharge only with the charger specified by the
manufacturer. A charger that is suitable for one
type of battery pack may create a risk of fire when
used with another battery pack.
b) Use power tools only with specifically
designated battery pack. Use of any other battery
packs may create a risk of injury and fire.
c) When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws, or other small metalobjects
that can make a connection from one terminal to
another. Shorting the battery teminals together
may cause burns or a fire.
d) Under abusive conditions, liquid may be
ejected from the battery; avoid contact. If contact
accidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
6) Service
a) Have your power tool serviced by a qualified
repair person using only identical replacement
4
parts. This will ensure that the safety of the power
tool is maintained.
2

Specific Safety Warnings

■Do not use the charger under the rain or when
it is wet. Failure to observe this can cause serious
injury or death due to electric shock.
■Do not insert metal wire or any conductive
object through the ventilating opening of the
charger. Failure to observe this can cause serious
injury or death due to electric shock.
■Do not attempt to disassemble the charger
and keep the charger out of the reach of children.
If the cord of the charger has been damaged,
replace or repair it immediately. Using the charger
with damaged cord may cause electric shock.
Electric shock may cause injury.
■Do not throw the battery into the live fire.
In the fire, the battery may explode due to high
temperature and cause serious injury.
■Do not short the terminals of the battery If
the terminals of the battery is short circuited,
excessive current will flow and fire or explosion
may occur causing serious injury.
■Avoid strong impact on the battery and do not
pierce the battery case with a sharp object. Fire or
explosion may occur causing serious injury.
■Store the battery indoors at 0 ~40 and avoid
direct light and closed hot and humid places. Fire
or explosion may occur causing serious injury.
Careless operating of the switch may cause a
serious injury by the rotating part of the tool.
■Make sure the battery is attached in the body
of the tool tightly before you start operation. When
the battery is not attached tightly, it may be fallen
during the operation and cause an injury in the top
of your foot.
■Charge only Keyang appoved rechargeable
batteries. Other types of batteries may burst
causing personal injury and damage.
■Do not disassemble battery.
Incorrect reassembly may result in a risk of electric
shock, electrocution or fire.
■Accessories may be hot after prolonged use.
When removing the bit from the tool avoid contact
with skin and use proper protective gloves when
grasping the bit or accessory.
■Keep the battery from being overheated.
If overheated battery is inserted, high temperature
standby is indicated and charging can only start
after the battery has been cooled down.
When the battery is overheating due to continuous
operation, in order to protect the battery
performance will automatically shut off the power.
■Leaving the battery for a prolonged time

Werbung