Translation of original operating instructions

6. Electrical connection

The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
Only use an extension cable with a cable section (3 x 1.0 mm²) and rubber sheath which at
least corresponds to that of the unit's own connection cable (see "Technical data", cable type)
and which is labeled with the relevant abbreviation according to the VDE (German Association
for Electrical, Electronic & Information Technologies). The mains plug and other connections
must be splash proof.
The mains plug of the automatic control system connects directly to electrical mains through a suitably grounded
(SCHUKO) mains socket which is to be installed properly. During operation, the green indicator light shows the
presence of voltage within the system. The mains plug of the pump is to be connected to the socket of the Brio
2000 M.

7. Putting into operation

Please avoid any direct influence of moisture on the device (for instance when operating
irrigators). Do not expose the unit to rain. Make sure there are no dripping connectors above
the device. Do not use the device in wet or moist environments. Make sure that the device
including any electrical plug connectors are installed in a flood-proof location.
Prior to putting the unit into operation, please fill the suction line and the pump casing completely with liquid. Plug
the mains plugs of the pump into the socket of the Brio 2000 M. Then use a properly installed grounded (earthed)
mains socket to connect the Brio 2000 M directly to mains. The green indicator lamp on the Brio 2000 M goes on
to indicate the presence of voltage. Subsequently, switch the pump on. After the pump has cut out automatically,
the highest-located consumer should be opened. As soon as the water is running smoothly, the process of putting
into operation is completed.
If no water is actually being discharged, please extend the time for putting the device into operation beyond the
time span set in the electronic pump control. To do so, please keep the "START PUMP" key on the Brio 2000 M
depressed until the priming process is completed and water is being discharged.
If after approximately 1 minute this measure fails, too, please disconnect the Brio 2000 M from mains and repeat
the steps described for putting into operation.

8. Interruption and Resumption of the Operation in the Case of Dry-Running

In the case of dry running / absence of water, the Brio 2000 M electronic pump control will ensure that the pump
will cut out. In addition, the red "ERROR" indicator lamp will light up. This protective feature will prevent a the
pump from cutting in automatically again. To resume operation, the "START PUMP" key of the electronic pump
control has to be operated. Before that, make sure to remove the cause of the dry-running.

9. Maintenance and troubleshooting

Prior to carrying out any maintenance work, the devices must be separated from the electrical
mains. If you fail to separate the unit from mains, there is a risk of an inadvertent start of the
pump.
We decline any liability for damage caused by inappropriate repair attempts. Any damage
caused by inappropriate repair attempts will avoid all warranty claims.
Regular maintenance and thorough care will reduce the danger of possible malfunction and contribute to an
extension of the lifetime of your unit.
If the pump is not in use over some extended period of time, both the devices and the entire system should be
emptied using the devices provided for this purpose. Water left in the pump may freeze in case of frost and thus
cause considerable damage.