Fault

Possible cause

Motor does not work
Motor, cable or plug defective, fuses burnt
The motor starts
Voltage too low, coils damaged, capacitor
up slowly and does
burnt
not reach operating
speed.
Motor makes exces-
Coils damaged, motor defective
sive noise
The motor does not
Circuits in the network are overloaded
reach its full power.
(lamps, other motors, etc.)
Motor overheats
Overloading of the motor, insufficient cool-
easily.
ing of the motor
Saw cut is rough or
Saw blade dull, tooth shape not appropri-
wavy
ate for the material thickness
Workpiece pulls
Excessive cutting pressure and/or saw
away and/or splinters
blade not suitable for use
36 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Remedy
Arrange for inspection of the machine by a
specialist.
Never repair the motor yourself. Danger!
Check fuses and replace as necessary
Contact the utility provider to check the volt-
age. Arrange for inspection of the motor by
a specialist. Arrange for replacement of the
capacitor by a specialist
Arrange for inspection of the motor by a spe-
cialist
Do not use any other equipment or motors on
the same circuit
Avoid overloading the motor while cutting,
remove dust from the motor in order to ensure
optimal cooling of the motor
Re-sharpen saw blade and/or use suitable saw
blade
Insert suitable saw blade