Technical Data
Model
Model No.
Plug
Nominal voltage
Rated power *)
Protection class
Degree of protection
Max. speed of motor
Suction capacity
Tank capacity
Max. operating pressure
Sound pressure level (L
)@7m
pA
Uncertainty K
Sound power level (L
)
WA
Uncertainty K
Guaranteed sound power level (L
WA
Lubrication
Weight
Dimensions
Ambient temperature
Ambient humidity
Max. altitude
Max. setup inclination
Noise
The values given in these instructions have
been measured in accordance with a stand-
ardized measurement procedure specified in
EN 3744 under operation conditions according
to point 9 Part B Annex III EU-RL 2000/14/EC
and can be used to compare machines.
It may be used for a preliminary assessment
of exposure.
160
EN
Pattfield Compressor 24L
PE-1024
PE-1024CH
10468364
10468365
EU plug
Swiss plug
220 – 240V~, 50 Hz
750 W (S3/50%)
I
IP30
1450 min
-1
129 l/min
24 l
8 bar
58 dB(A)
3 dB(A)
76.5 dB(A)
1.9 dB(A)
)
78 dB(A)
oil free
23.2 kg
58 x 25.5 x 58 cm
+5 °C to +40 °C
> 50%
1,000 m
10°
Troubleshooting
Problem
Cause
Compressor doesn't
No power supply
work
Power supply too low
Outdoor temperature too low
Motor overheated
Compressor runs, but
Safety
valve 10
generates no pressure.
Sealing is broken
Drain screw for condensation
water 12
leaky
Compressor runs, pres-
Hose connection leaky
sure is shown at the
pressure gauge, but
tools don't run.
Fast coupling at air outlet
leaky
Pressure is set too low at the
pressure
regulator 4
Warning! Service work on the safety valve and on all other pressure parts must be
performed only by qualified service.
Remedy
Check cable, power plug, fuse
and power outlet
Avoid too long extension cords
Do not run compressor at out-
door temperatures below +5 °C
Let motor cool down. Remove
overheating cause if possible.
Press the overload
switch 9
leaky
Contact service
Check sealings. Have sealings
replaced by your HORNBACH
store
Tighten screw. Check sealing of
drain screw. Replace sealing if
necessary
Check compressed-air hose
and tools, replace if necessary
5
Contact service
Turn pressure
regulator 4
EN
161