Troubleshooting

Problem
Unit does not operate
No mist output
Weak mist output
White deposit around the appliance
Technical specifications
Mains voltage
Power consumption
Humidity output
Suitable for rooms up to
Water capacity
Dimensions
Weight (empty)
Operating noise level
Accessories
(optional) Ionic Silver Stick® (ISS)
* when used with pre-heating to 80°C
Possible cause
Power plug not plugged in
No water in the tank (Empty indicator flashing)
Desired humidity level lower than actual
Cleaning agent residues
Water temperature too low
Mineral deposits on membrane
Demineralisation cartridge exhausted
230 V / 50 Hz
45 / 140 W*
400 / 550 g/h*
60 m
/ 150 m
2
3
7.5 liter
350 x 280 x 440 mm
4.0 kg
< 25 dB(A)
Demineralisation cartridge
What to do
Plug in power plug into mains socket
Fill tank with water
Increase humidity setting
Rinse with clear water
Set mist output to maximum. The appliance will work properly
again after 10 minutes.
Clean membrane
Replace demineralisation cartridge or resin