NOTE ON DRAINPIPE INSTALLATION
When using an extended drainpipe,
tighten the indoor connection with an
additional protection tube to prevent it
from pulling loose.
 The drainpipe should slope downward at
a gradient of at least 1/100 to prevent wa-
ter from flowing back into the air condi-
tioner. To prevent the pipe from sagging,
space hanging wires every 1-1.5m (39-59").
 If the outlet of the drainpipe is higher than
the body's pump joint, provide a lift pipe
for the exhaust outlet of the indoor unit.
The lift pipe must be installed no higher
than 75cm (29.5") from the ceiling board
and the distance between the unit and
the lift pipe must be less than 30cm (11.8")
(depending on models).
 Incorrect installation could cause water to
flow back into the unit and flood.
To prevent air bubbles, keep the drain
hose level or slightly tiled up (<75mm / 3")
(some models ).
(A)
(B)
NOTE:
When
drainpipes, install the pipes as illustra-
ted in the following Figure.
Ceiling
1 - 1.5m
≤30cm (11.8")
(39-59")
≤53cm
(20.8")
22cm
(8.6")
0 - 75mm
(3")
1 - 1.5m
(39-59")
connecting
multiple
(A)
0-53cm
(20.8")
≥10cm
(4")
(B)
Pass the drain hose through the wall hole.
Make sure the water drains to a safe
location where it will not cause water
damage or a slipping hazard.
NOTE: The drainpipe outlet should be at
least 5cm (1.9") above the ground. If it touches
the ground, the unit may become blocked
and malfunction. If you discharge the water
directly into a sewer, make sure that the
drain has a U or S pipe to catch odors that
might otherwise come back into the house.
How to install the conduit installation plate
(if supplied)
1. Fix the sheath connector (not supply) on
the wire hole of the conduit installation plate.
2. Fix the conduit installation plate on the
≤75cm
(29.5")
chassis of the unit.
≤75cm
(29.5")
Cord conduit
The conduit
installation plate
26
Vent
Chassis
Conduit
installation
plate
≤75cm
(29.5")
screws
(not supply)
V.2