Operation
PLASMA CUTTING SERIES EQUIPMENT
9
32
10
PLASMA CUTTING SERIES EQUIPMENT
DO NOT TOUCH the electrode wire while it is being
fed through the system. The electrodewire will be at
ARNING
welding voltage potential.
1. Digital Ammeter
The digital Ammeter is used to display the actual output current of the power source.
2. Power Indicator
The green power indicator will be illuminated when the welder is turned ON and indicates
the presence of power.
3. Thermal Overload Indicator Light
This welding power source is protected by a self resetting thermostat. The indicator will
illuminate if the duty cycle of the power source has been exceeded. Should the thermal
overload indicator illuminate the output of the power source will be disabled. Once the
power source cools down this light will go OFF and the over temperature condition will
automatically reset. Note that the mains power switch should remain in the on position
such that the fan continues to operate thus allowing the unit to cool sufficiently. Do not
switch the unit off should a thermal overload condition be present.
4.Cutting current adjustment
Clockwise rotate to enlarge the current, and anti-clockwise rotate to reduce the current.
5. Positive Welding Output Terminal
The positive cutting terminal is used to connect the cutting output of the power source
to the appropriate welding accessory such as earth clamp. It is essential, however, that
the male plug is inserted and turned securely to achieve a sound electrical connection.
6. Plasma torch connection
Plug in the plasma torch to connect it to the machine. Are you goingMake sure the
plug is inserted and tightened to the electricity and gas supplymaintain.
7. Pilot connection
The plasma torch is connected to the pilot port on the machine. Here is theArc generated
by pressing the button on the burner. (contactless ignition).
8. Plasma torch control Switch
Remote control switch receptacle is used to connect a plasma torch trigger switch:
To make connections, align keyway, insert plug, and rotate threaded collar fully clockwise.
The socket information is included in the event the supplied cable is not suitable and it is
necessary to wire a plug or cable to interface with the receptacle.
9. Power switch
before using the machine. Pull the switch to the closure state of "AN" to operate themachine,
and pull the switch to "AUS" after use. Turn off the power input, and the machine will stop
operating.
10. Gas input port
The gas interface is with the outlet connection of the pneumatic valveconnected, and
after the connection is completed, it is detected whether aThere is a gas leakage
phenomenon (As shown in section 3.2 Air pressure valve installedand operated).
Operation