Proper ventilation
 The hob must be ventilated properly. The air inlet (D) and
outlet (E) must never be blocked or covered (s. fig. below).
Always keep the appliance in proper condition.
A Wall cupboard = min. 450 mm
Extractor hood = min. 760 mm
B min. 50 mm
C Ventilation slot = min. 30 mm
D Air inlet
E Air outlet = min. 5 mm
X Distance to the front/rear = 150 mm
Y Space underneath = 20mm
(1) Before installing the hob, the adhesive seal has to be fixed
on the bottom edge of the hob properly.
 The seal has to be fixed properly. The outer side of the
seal must match the bottom outer edge of the hob (s. fig.
below). The seal must be fitted tightly on the bottom
edge of the hob (no overlaps, no gaps etc.) to prevent
liquids etc. from entering the installation opening
subsequently.
1 Seal
2 Hob
3 Worktop
4 Outer edge of the hob
5 Outer side of the seal
6 Bottom of the hob
46