Herunterladen Inhalt Inhalt Diese Seite drucken

Lenoxx Designhauben PARSIFAL 90 – 120 Installationanleitung Und Betriebsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

When the suction function is operating, exhausting the filtered air on the outside, a suitable compensation
system must be used according to current standards in force. The diameter of the fume exhaust pipe must be the
same or greater than the diameter of the downdraft pipe union.
There must be sufficient ventilation in the room where the downdraft is installed, to allow the simultaneous use
of other appliances that use gas or other fuels.
ASSEMBLY INSTRUCTIONS
Make a hole in the downdraft approximately 50mm from the work top hole.
For the dimensions of the hole, see drawing here below.
In the INOX version, the gluing of the cover (as rule, use the same material of the work top) of the downdraft,
must be performed in the same place after finishing the assembly of the downdraft.
The support for the gluing of the cover is supplied with the downdraft.
The controls must be assembled in order to guarantee an eventual attendance of technical assistance.
In the kitchen furniture, provide in front or behind of the downdraft a removable wall.
It is possible to connect on the front or on the back part of the downdraft a tube of diameter 150 or 200mm
according to the suction motor used. It is possible to connect on the side of the downdraft a tube of diameter
150mm on both sides and preferably on two heights.