Herunterladen Inhalt Inhalt Diese Seite drucken

Clean The Brush Roll; Clean The Pipe; Troubleshooting - GreenWorks VUG403 Bedienungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
EN
Be aware that a rest of dust and debris can fall out the filter
when pulling too quickly.
6. Turn the strainer (26) counter-clockwise and remove it.
7. Shake the filter and empty the debris into a waste bin.
8. Run water through the filter from a hose or spigot.
9. Allow the filter to completely dry before storing or
picking up debris.
Do not operate the machine without collection bin or filter.
9.2

CLEAN THE BRUSH ROLL

Figure 12
Turn off the machine before maintenance or troubleshooting
to reduce the risk of electric shock or injury.
1. Press the release button (8) to disconnect the motorized
brush head (4) from the vacuum.
2. Push the brush roll release button (27) so the side plate
(28) will release.
3. Lift the side plate (28).
4. Take the brush roll (29) out.
5. Clean up the debris and hairs.
6. Run water through the brush roll from a hose or spigot.
7. If your brush roll chamber is dirty, use the rag or towel to
clean it.
8. Allow the brush roll and chamber to completely dry
before storing or picking up debris.
9.3

CLEAN THE PIPE

Figure 13
Turn off the machine before maintenance or troubleshooting
to reduce the risk of electric shock or injury.
1. Press the release button toremove the extension pole and
floor brush.
2. Empty the collection bin.
3. Remove the brush roll.
4. Check the pipes of the vac, brush and extension pole.
5. Pump the debris out or use the wire to clean the pipes if
pipes are blocked.
NOTE
WARNING
WARNING
NOTE
English
10

TROUBLESHOOTING

Problem
The machine
doesn't work.
Dust discharges
from machine.
Loss of suction
Errors
Problem
Only one red LED
light is on and
flashes then ma-
chine shutdown
automatically.
The wand debris
light (19) is on,
LED lights turn to
red and the ma-
chine shutdown
automatically.
8
Possible cause
Solution
The switch or mo-
Speak to service
tor is defective.
center.
The battery is not
Follow the manual
inserted correctly.
to reinstall the bat-
tery.
The battery is out
Charge your bat-
of power.
tery.
The filter has dam-
Replace the filter.
age.
The filter isn't in-
Properly reinstall
stalled.
the filter.
The filter is not
Clean or replace
functional.
the filter.
Clean or replace
The filter clogs.
the filter.
Clean or replace
The filter clogs.
the filter.
The collection bin
Empty the collec-
is full.
tion bin.
Possible cause
Solution
Battery is dead.
Place the machine
on charging sta-
tion.
1. Remove the
battery pack.
2. Remove the
extension pole
from the vac-
uum.
Clear wand debris.
3. Pump the deb-
ris out.
4. Call service
center if it still
doesn't work.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis