TROUBLESHOOTING / MESSAGES
When lights are flashing, you should look for the reason, and act before using the toilet. Immediate action is
required when irregularities such as odours, poor incineration or system failures occur, in order to avoid
consequential damage and unnecessary repair costs.
Error
RED
Ash container
FLASHING
should be emptied
Alternately
Ash container must
STEADY
be emptied.
Toilet locked.
Burner fan error
FLASHING
Ventilation fan error
FLASHING
Malfunctioning
hatch mechanism
FLASHING
Ash container out
FLASHING
of position
Heating circuit
interrupted
Toilet lid sensor is
FLASHING
triggered
Malfunctioning
temperature sensor
Other sound/light signals
• >11.5V is the normal operating voltage (green LED shines continuously)
• <11.0V is low voltage (green LED is blinking)
• <10.5V is the minimum permitted battery voltage (10 beeps + green light blinking continuously after 1.5 min).
The gas supply is disconnected.
• <9.5V is a critically low voltage (10 low beeps once and immediate disconnect)
Resetting the electronic
During cleaning and fault finding, resetting the electronic unit may sometimes be helpful. Do this by pushing the
start button, this will cause a short beep to be heard. Hold down the button for about 8 seconds until a long beep
is heard, then release button.
14
YELLOW
GREEN
FLASHING
STEADY
Alternately
STEADY
STEADY ON
ON
FLASHING
FLASHING
OFF
FLASHING
STEADY
OFF
STEADY
FLASHING
STEADY
OFF
FLASHING
STEADY
OFF
OFF
FLASHING
FLASHING
SOUND
ACTIONS
1
3 BEEPS
ON
3 BEEPS
1
10 SECONDS
ON
APART
1
2
3
1
10 BEEPS
2
3
1
2
3
10 BEEPS
ON
4
5
6
1
2
3 BEEPS
ON
3
1
2
3
CONTINUOUS
ON
BEEPS
3
4
1
NONE
2
ON
3
1
CONTINUOUS
2
BEEPS
3
Remove and empty the ash container
Remove and empty the ash container
Check fan for obstructions and ensure that fan blades
are rotating properly
Reset toilet "hold down start"
Open lid until red light flashes, close lid and push start
If error persists, call support
Check fan for obstructions and ensure that fan blades
are rotating properly
Reset toilet "hold down start"
Open lid until red light flashes, close lid and push start
If error persists, call support
If toilet is warm, reset toilet
Open lid until red light flashes, close lid and push start
If unsuccessful, reset toilet, insert a bowl liner and
pour 3 cups of water into the liner, close lid and push
start
If unsuccessful wait until the toilet has cooled (fan
stopped)
Restart toilet and open lid when the hatch is opening,
remove stuck items manually
If problem persists, call support
Adjust the position of the ash container, rotate to the
left side
Control that the stop pin on the container is intact
Visually check the condition of the magnet on the
container
If problem persists, call support
Reset the toilet and wait 15 minutes.
Control that you have gas
Check bimetal thermostat on right hand side of toilet.
'Unscrew grey plug' and 'push' on fuse inside with
finger, do not use any sharp objects.
If the fuse was triggered, you will hear a click. See
section 5.0 page 25.
If the fuse was not the problem, restart toilet and try to
start toilet, repeat a couple of times.
If the problem is not solved, call for service
Check the magnet situated inside the toilet lid
Close lid
If problem persists, call support
Reset toilet
Open lid until red light flashes, close lid and push start
If failure persists, call support