High pressure failure
TS4
Low pressure failure TS5
Water flow failure TS1
Over heating protection
for water temperature
(d2- TH5) in heating
mode
d6-TH3 Exhaust too high
protection
1. Ambient temperature is too high
2. Water temperature is too high
3. Water flow is too low
4. Fan motor speed is abnormal or fan
EE01
motor is damaged under cooling mode
5. Gas system jammed
6. High pressure wire is loose or damaged
7. Too much refrigerant
1. EEV has blocked or pipe system is jammed
2. Fan motor speed is abnormal or fan
EE02
motor is damaged under heating mode
3. Gas leakage
4. Low pressure wire is loose or damaged
1. The wiring of water flow switch is loose or
EE03 Or
water flow switch damaged
"ON"
2. No/Insufficient water flow.
1. Low water flow
2. Water flow switch is stuck and the water
supply stops
3. TH5 outlet water temperature sensor is
EE04
abnormal
4. The difference of outlet water
temperature and set temperature is 7℃ or
above in heating mode
1. Lack of gas
2. Low water flow
EE05
3. Piping system has been blocked
4. Exhaust temp. sensor failure d6-TH3
5. Ambient temperature is too high
1. Choose the silent mode.
2. Check the water flow or filtration
pump
3. Check the fan motor under cooling
mode, replace a new one if it is
abnormal.
4. Check and repair the refrigerating
system
5. Reconnect the high pressure wire or
replace a new high pressure switch
6. Check and repair the refrigerating
system
1.Check the EEV and piping system Check
the motor
2. Check the fan motor under heating
mode, replace a new one if it is abnormal
3. Check refrigeration system or check
the pressure value through the
high-pressure gauge.
4. Reconnect the low pressure wire or
replace a new low pressure switch
1. Check the wiring of water flow switch
or change a new one.
2. Check the filtration pump or the
waterway system if there is air or
jammed inside
1. Check the water flow switch if it works
well
2. Check the filtration pump or the
waterway system if there is air or
jammed inside
3. Check TH5 outlet water temperature
sensor or replace a new one.
4. Change the set temperature.
1. Check the pressure gauge, and fill with
some gas if it is lack of gas
2. Check the filtration pump or the
waterway system if there is air or
jammed inside
3. Check the piping system if there was
any block
21