Herunterladen Inhalt Inhalt Diese Seite drucken

Toro Tempus Air MS Bedienungsanleitung Seite 4

1-4 sensoreingänge
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Toro Tempus Air MS
Step 4
SENSOR INSTALLATION
To ease the sensor installation we advise to follow the MyToroTempus mobile application instruction.
1. Get closer than 10 meters from Tempus Air MS and make sure your smartphone's Bluetooth is turned on.
2. Launch MyToroTempus app from your smartphone or tablet.
3. Select the Tempus Air MS previously installed. (The two devices, smartphone and MS module, must be connected
via Bluetooth)
4. Click on "Add a sensor"
5. Select the type of sensor you want connect to your Tempus Air MS.
6. Select the sensor you want connect to your Tempus Air MS.
7. To properly connect the wiring and complete the sensor installation, follow the next steps described in the app.
WIRING
Configurable acquisition inputs (3 inputs for S4 model, 1 input for S1 model)
• Dry contact (rain sensor, anemometer, ...)
• Pulsive (flowmeter, ...)
• Analog 0-3.5V (humidity sensor, solar radiation...)
Red wires: 3.5V power supply
Note: the Tempus Air S1 have only 1 Configurable acquisition input (three-wire entry) and it doesn't have
temperature sensor input (two-wire entry)
4
Temperature sensor input.
PT100 Standard (not present in S1 model)
Data
3,5V