Operation

Display and light

To turn display (5) "on", either:
• Push button "1" (4) († fig. 3)
• Squeeze the trigger/switch.
To turn light "on/off":
• Push button "1" (4).
Display and light shut off automatically after
30 seconds if gun is not operating.

Speed selection

Pressing button "2" (4) switches the tool
between high and low pump speed.
The letter "L" or "h" will be displayed on
the screen.
High delivers 160 ml/min. (5.5 oz/min.) at
69 bar (1 000 psi) back pressure.
Low delivers 100 ml/min. (3.5 oz/min.) at
69 bar (1 000 psi) back pressure.
Motor speed increases automatically from
"L" to "H" if back pressure exceeds
2 500 psi (172 bar).
Switch units
Switch units of measure between ounces
or grams by holding button "1" (4) for
15 seconds († fig. 3).
5
4
4A
Control/monitor grease
application
Refer to the display representations in fig. 4.
1 To set display reading to zero, press set but-
ton "1" (4) for 3 seconds († fig. 4A).
2 Squeeze trigger to run and stop the gun at
desired output. (0.6 oz. Is shown in
fig. 4B).
3 Press button "2" (4) to switch between low
and high. († fig. 4C)
4B
12
4 Press button "1" (4) for 15 seconds to switch
between ounces and grams († fig. 4C).
NOTE
Grease meter displays output only if grease
gun is adequately primed.
4C