Herunterladen Inhalt Inhalt Diese Seite drucken

Inspection; Operation - Lincoln PowerLuber series Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSPECTION

Visually inspect for damaged, loose or miss-
ing parts. If equipment is worn or damaged,
remove from service. Contact an authorized
service center for damage assessment or
repair.

OPERATION

Changing "L" or "H" Mode
To change the mode of operation:
To prevent damage to the gears in the
transmission, the motor must be com-
pletely stopped before changing the lever
to the "L" or "H" (low or high) mode of
operation.
"L" (low output/high pressure)
"H" (high output/low pressure)
When motor is not running, push the lever
(Fig. 1) until letter "L" or "H" will be completely
visible in the window.
In case the lever is not completely shifted/
engaged, hold this lever and bump the switch
to engage gears.
High output is recommended if the tool is
used to lubricate large bearings not requiring
high pressure, beyond 3,000 psi (206 bar).
Also, high output is recommended if tool is
used to refill small reservoirs.
Low output is recommended if the tool is
used in construction, mining applications and
general lubrication. Low output will provide
the maximum pressure of up to 7,500 psi
(517 bar) the tool is capable of producing.
It is normal for batteries to lose their power
retention capacity over hundreds of charge
cycles. Replace the battery when this hap-
pens.
Turning Display and LED light
"ON"/"OFF"
To turn display and LED light "ON":
-push either key or
-gently squeeze the trigger/switch;
To turn it "OFF":
-push key "B" 3 sec. or
-wait 30seconds for self shutoff.
Form 404264
Models 1860, 1862, 1862E, 1864
PowerLuber Grease Gun (Lithium)
Display "ON"
Grease flow monitoring.
Some OEM's recommends the exact amount of
grease to lubricate critical bearings.
To deliver the desired amount of grease:
1. Press set key "A" 3sec. to set display reading
to zero.
2. Run and stop the gun at desired output.
3. Reset with Key A and lubricate next bearing.
4. Press key "B" 1 sec to view total (accumu-
lated) output.
Replacing the grease cartridge or
refilling the tube.
1. Prime the Power Luber after each refill or
grease cartridge change. To prime, operate
the gun until grease flows from hose. Use
vent valve (Fig.1) to expel air pockets.
2. Press set key "A" and "B" simultaneously 3
sec to reset all. (output, accumulated output
and grease level indicator.)
3. Press set key "A" 1 sec to display symbol
"grease level full".
Display "OFF"
Figure 2
Figure 3
Figure 4
Page Number - 7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis