11. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!

12. Cleaning

• The device has a twist-clean function (3). (Fig. 1)
• If the piece of red rubber in the clogging indicator
(13) has been pushed upwards, it is time to clean
the device.
• To do this, set the rotary switch (5) from "Run" to
"Clean" and open the filter drain (12).
• Now turn the twist-clean crank a few times to clean
the filter insert (14) and to discharge the debris.

13. Storage

Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature lies between 5 and 30 ˚C.
Store the tool in its original packaging. Cover the tool
to protect it from dust or moisture. Store the operating
manual with the tool.

14. Maintenance

m Warning!
Always pull out the mains plug before carrying out ad-
justments on the device.
Replacing the UVC lamp (Fig. 9-11)
1.
Pull out the rotary switch (5).
2.
Remove the screws underneath.
3.
Remove the blue cover (4).
4.
Remove the screws marked in figure 10.
5.
You can then remove the entire unit.
6.
Replace the lamp and follow these steps in reverse
order.
m Attention!
Replace the UVC lamp once a year or every 10,000
operating hours.

Service information

With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consuma-
bles.
Wearing parts*: UVC lamp, filter element
* may not be included in the scope of supply!
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.