Function
Action
Peel off label, 1 x • wait for
1 x
Commissioning
Note: no during background measurement
wait for
Normal operation (water flows)
Special functions
Waterflow duration:
Press • 1 x for 2 s (min.) – then release
SETTING
Press • 1 x for 5 s until 1 x
(Factory setting approx. 1 s)
Press • 1 x (water flows) and keep pressing until the
desired water flow duration has been reached
Continuous water flow: ON
Press • 1 x for 2 s (min.) – then release
(Factory setting approx. 2 min)
Press • 1 x for 2-4 s
Continuous water flow:
Press • 1 x
OFF
Continuous water flow:
Press • 1 x for 2 s (min.) – then release
SETTING
Press • 1 x for 2-4 s
(Factory setting approx. 2 min)
Press • 1 x and keep pressing until the desired
water flow time has been reached.
Flashing will start after 5 s
Pause: ON
Press • 1 x for 2 s (min.) – then release
(Factory setting approx. 2 min.)
Press • 2 x
Pause: OFF
Press • 1 x
New calibration
Press • 1 x for 2 s (min.) – then release
(Ambient background
Press • 2 x
measurement)
Press • 1 x for 5 s until 4 x
release – wait 15 s – do not place hands within
sensor area (water flows after 10 s), after
which an new ambient background measure-
ment will be defined
Hygienic rinse
Press • 1 x for 2 s (min.) – then release
24 h / 12 h: ON / OFF
Press • 1 x 24 s and hold until the desired
(Factory setting: OFF)
setting has been reached
Release button
Emergency shut-off
(static object in sensor area)
Transmission power:
Press • 1 x for 2 s (min.) – then release
SETTING
Press • 2 x
(Sensor range)
Press • 1 x and hold, after 5 s 4 x
continue to press until the desired transmis-
sion power is achieved. An automatic back-
ground measurement will then take place – do
not place hands in the sensor area during this
time (approx. 20 s)
Display
Battery life
DE/FR/IT/EN
Infratronic-N: Functions
•
= Infrared button (IR)
= Hand / Object in sensor area
= Flashing LED
(green
(red), then release
(red) - then
(red) then
or red)
Display
Description
1 x
(green)
Automatic background measurement starts
1 x / s
(red)
Background measurement finished, fitting ready for use
1 x
(green)
Water flows: ON
1 x
(green)
1 x
(red)
Water flow duration: adjustable from 0 to 10 s
1 x
(green)
Acknowledgement
Continuous waterflow: ON
1 x
(green)
1 x
(green)
Acknowledgement (Automatic shut-off after „Continuous
1 x
(green)
water flow ON" duration – if not switched off manually)
Continuous waterflow: ON
1 x
(green)
Minimum: 1 x
4 x
(green)
Maximum: 40 x
1 - 40 x
(red)
Flow time confirmation
1 - 40 x
(red)
Acknowledgement
1 x
(green)
1 x
(green)
1 x
(green)
1 x
(red) fast flashing
Confirmation Pause: ON
whilst „Pause ON" active
Acknowledgement (automatically goes back to normal
1 x
(green)
mode after 2 min – if not switched off manually)
1 x
(green)
1 x
(green)
(red) fast flashing
4 x
(red)
1 x
(green)
Flashing will commence after 24 s
1 x
(green)
1 x
1-3 x
(red)
2 x
3 x
The flow duration for the hygienic rinse is identical to
that for the „Continuous water flow"
Acknowledgement
1 x
(green)
Water flow ist switched off after a continuous detection period
of 90 s. A new background measurement is then carried out
1 x
(green)
1 x
(green)
(red) fast flashing
Transmission power: minimum = 1 x
4 x
(red)
Acknowledgement
1 x
(green)
Level 1: Battery weak - water still flows
Lights up
(red)
Level 2: Battery depleted - water does not flow
Flashes
(red)
8
(red) = 30 s
(red) = 20 min
(red) = hygienic rinse OFF
(red) = hygienic rinse ON - 12 h after last use
(red) = hygienic rinse ON - 24 h after last use
(red)
maximum = 8 x
(red)