FLAME DETECTION SYSTEM CHECK
With the burner switched off, connect a DC microam-
1
min. 1,5 µA
meter with a 0÷50 or 0÷100 µA dial. When the burner is
running, and is properly adjusted, the value read must be
LANDIS
steady and never be smaller than 1,5 µA(Landis).
LME 11 / LME 21