Troubleshooting

1. Difficulties during commissioning
Situation
Spark plug
No ignition
spark
other
Compression
Weak
ignition
The carburetor does
spark
not pump oil
anymore.
regular oil supply
but weak
compression
Regular oil supply
and proper ignition
spark
Cause
Carbon deposit between the
diodes of the spark plug
ignition coil defective flywheel
magnet too weak
Too much gasoline in the
combustion chamber, bad fuel or
water in the tank
Oil line blocked
Piston rings worn, spark plug not
screwed down, cylinder head not
tight wrong valve clearance or
ignition timing.
Poor contact between ignition cap
and spark plug
97
Solution
Clean the spark plug.
Adjust the gap
0.6~0.7mm, Replace
the spark plug
Replacing the ignition
coil or flywheel
Remove the spark
plug and allow to dry,
replace fuel.
Cleaning the
carburetor and
cleaning the pipes
Replace screw tight
replace or adjust
Replace or check