EO
Communication fault
E1
Room temperature sensor faulty
Fault in connection to room temperature sensor or other damage.
E2
Indoor coil temperature sensor faulty
Fault in connection to indoor coil temperature sensor or other damage.
E3
Outdoor coil temperature sensor faulty
Fault in connection to outdoor coil temperature sensor or other damage.
E4
Insufficient refridgerant
Faulty in cooling or heating function. No temperature change is detected on
the indoor coil sensor at first 20min after compressor start to work.
E5
Indoor/ Outdoor coil over heated protection
When cooling or dry mode, too high temperature on outdoor coil sensor.
When heating mode, too high temperature on indoor coil sensor.
E7
Compressor overload protection
The compressor is self-protected and stopped due to too high load.