Calibration

The digital spirit level has been calibrated in the factory for
maximum accuracy. If necessary, the digital spirit level
can be re-calibrated.
1. Clip the digital spirit level to a spirit level (Fig. 1).
2. Switch on the digital spirit level. Use an object that is
fine but not too sharp to press the recessed calibration
key CAL (7). The buzzer (3) starts to beep (Fig. 2).
3. Place the digital spirit level on a flat and level surface
and press the MODE key (6) once. Wait for a few
seconds until the buzzer beeps.
4. Place the spirit level reverse horizontal by 180º and
press the MODE key once. Wait until the buzzer beeps
(Fig. 3).
5. Place the spirit level vertically (in a right angle) and
press the MODE key once. Wait until the buzzer beeps
(Fig. 4).
6. Flip over the spirit level by 180º and press the MODE
key once. Wait until the buzzer beeps (Fig. 5).
7. Calibration is completed when the buzzer has stopped
beeping.
Note: Ensure the digital spirit level is kept absolutely
steady during calibration.