Product description
SKQ 40-00 = 8PSK/QPSK - QAM quattro module (SKQ 40-04 with CI)
SKQ 80-00 = 8PSK/QPSK - QAM octo module (SKQ 80-02 with CI)
The modules transmodulates 8PSK/QPSK into QAM.
SKQ 40-00M = Multituner - QAM quattro module (SKQ 40-04M with CI)
SKQ 80-00M = Multituner - QAM octo module (SKQ 80-02M with CI)
The modules transmodulates DVB-S/S2/T/T2/C/Cx into QAM.
Mounting and Installation:
Before inserting or changing a module, pull the mains plug of the
headend base unit from the socket!
The headend modules can be operated either in a headend base units (1)
or stand-alone with the external power supply unit (2).
The module is supplied with power by DC patch cable (3). While looping
the modules through, a maximum of 3 x SKQ 80-0x or 4 x SKQ 40-0x can
be connected together.
It is imperative to use a power supply unit with sufficient output
power for your application!
At the input the modules have a remote supply voltage for the LNB. For
receiving DVB-T/T2 or DVB-C the LNB power has to be switched off
before connecting a antenna cabel to one of the HF inputs! You will
find this setting in the configuration in phase 1.
3
Scope of delivery:
All manuals and user guides at all-guides.com
1 × Headend module
1 × DC connection cable
1 × Quick start guide
2
3
1
Display elements and connectors
Notes
4
Detailed operation instructions of the
modules are available at www.axing.com
4
Observe the operation instructions of the
used headend base unit!
4
Observe the operation instructions of the
used power supply unit!
4
If the device is mounted in the headend base
unit, the connection to the equipotential
bonding has to be done via the headend base
unit.
4
If the module is mounted external a headend
base unit the module and the power supply
unit must be connected to the equipotential
bonding according to EN 60728-11. Use the
equipotential bonding connection at the
device.
1
4/8 × LED indicators MPEG data stream modulator
Error (red) = Fill level >95%
OK (green) = Fill level OK
2
4/8 × HF input
3
1/2 × RJ-45 Ethernet port
4
4/8 × HF input LED indicator:
Orange = MPEG data stream present,
Off = no MPEG data stream
5
Equipotential bonding connection
6
1/2 × HF output
7
Fan
8
2 × DC input/output
Common Interfaces
CAM2
CAM4
CAM1
CAM3
CAM1
left
Note: Each CAM corresponds and
gets access only to according tuner.
CAM 1 - tuner 1
CAM 2 - tuner 2
CAM 3 - tuner 3
CAM 4 - tuner 4
Configuration:
The device is configured via the graphical user interface of the
integrated web interface. To access the user interface, you need a
standard PC/laptop with a network interface and the actual
version of the installed web browser. To connect the network
interface of the module to the computer, you need a commercially
available network cable.
The SKT 80-0x contains two separate units. Each unit has its own
web interface and its own static IP address.
Accessing the configuration interface:
Default IP address of the SKQ 40-0x:
Default IP address of the SKQ 80-0x, left side:
Default IP address of the SKQ 80-0x, right side:
Subnet mask:
4
Change the IP address of your PC/laptop, e.g. to
192.168.0.11.
4
Now enter the IP address 192.168.0.145 in the web browser.
The configuration screen is password-protected:
4
Enter the default password Ramsen8262.
4
Click the "Enter password" button and then the "Open
page" button.
4
This will open the start page.
4
After the first log-in, the password should be changed.
CAM1
right
192.168.0.145
192.168.0.145