5. Commissioning

The device must be transported in an upright position. If it is stored or transported horizontally, it
must stand upright for at least 24 hours before it can be switched on (Fig. 1).
Fig. 1
5.1 Placing of the heat pump
The future location of the device should be easily accessible for convenient operation and maintenance.
It must be placed on the ground, ideally on a level concrete floor. Ensure that the ground is sufficiently sta-
ble and can support the weight of the device.
A water drainage device must be provided near the device to protect the installation area.
If necessary, the device can be raised using suitable mounting pads designed for its weight.
Ensure that the device is well ventilated, that the air outlet does not face the windows of neighbouring build-
ings and that the exhaust air cannot flow back.
The device must not be installed when oil, flammable gases, corrosive products, sulphur-containing com-
pounds or high-frequency devices are nearby.
To avoid soiling, do not install the device near a road or path.
To avoid annoying neighbours, ensure that the device is installed facing the least noise-sensitive area.
Operate the device as far as possible out of the reach of children.
Leave a free space of 50 cm at the sides and rear of the heat pump (Fig. 2).
Leave a free space of 2.5 m at the front of the heat pump in relation to walls.
Do not place any objects in front of or on the device. A minimum distance of 1 m from the front of the heat
pump must be ensured.
Fig. 2
Sound-absorbing underlays:
To minimise noise pollution caused by the vibrations of the heat pump, it can be placed on vibration-damping
underlays.
All that is required is to position an underlay between the feet of the unit and the bracket and to secure the heat
pump to the bracket with suitable screws.