4. CONSTRUCTION

A Housing
B On- / Off switch with blue indicator light
C UV-C special bulp
D Fan
A
C
D
B

5. OPERATION

5.1. Placement

Place the device on a firm surface approx. 2 metres ab-
ove the floor (if possible on something such as a shelf or
cabinet) to allow for optimal air circulation.
Warm, stuffy air rises. For maximum effect the device
should not be placed near an exhaust fan. Note that the
minimum room size should be 55 m

5.2. Commissioning and operation

1. Connect the OZONOS Aircleaner to an earthed 230-volt
mains connection.
2. Press the switch (B) to turn on the air purifier. The in-
dicator light on the switch lights up. The status light
of the UV-C bulb (C) glows blue. After 8,000 operating
hours the lamp must be changed, the status lamp now
lights yellow/orange.
3. It emits a gentle hum.
4. The device may heat up during operation.
5. To switch off, press the switch (B), the indicator light
turns off.

6. LIFESPAN OF THE UV-C BULB

The lifespan of the UV-C bulb (C) is 8,000 operating
hours. After 8,000 operating hours have been reached,
the status lamp lights up yellow/orange. The bulb must
then be replaced in order to ensure the device's continu-
ed effectiveness. If performance drops before the bulb
.
3
AIRCLEANER AC-I / AC-1 PLUS / AC-1 PRO | OPERATION & MAINTENANCE INSTRUCTIONS | 01.06.2022
*
Produced in accordance with DIN 9001:2015
* The AC-I of the brand OZONOS has been certified
and approved by TÜV Süd via our producer „Digital
Elektronik GmbH".

5.3. Treatment duration

The OZONOS Aircleaner is designed for long-term indoor
use. The optimum use of the OZONOS Aircleaner depends
on the type of application, the type and degree of inter-
nal air contamination, and the room size. Depending on
the level of contamination, two to four hours of treatment
time is sufficient to remove odours in a 55 m
25 m
room. We recommend uninterrupted use for people
2
prone to allergic and asthmatic reactions.
The OZONOS AC-1 PLUS and AC-1 PRO are not designed
for 24/7 use where people are always in the same room.
We recommend not staying more than 8 consecutive
hours in the room in which the device is in operation.
The OZONOS AC-1 PLUS and AC-1 PRO are particularly
suitable for professional use and for faster, more inten-
sive cleaning.
has reached around 8,000 operating hours or 36 months,
it must be checked for dust or other contamination. To
do this, please follow the instructions in point 7.1 or send
the device to OZONOS GmbH for inspection.