Herunterladen Inhalt Inhalt Diese Seite drucken

Lan Remote Control - Mitsubishi Electric LDT462V Benutzerhandbuch

46'' lcd display monitor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65
U-12
Remote control (continued)
5) Read command
The computer sends the command without datacode to the monitor.
After receiving this command, the monitor returns the command with datacode including the current status to the computer.
Example: When the computer asks the power status of the monitor, and the status of the monitor is powered-on.
Control command from computer
30 30 76 50 0D '0''0''v''P'[enter]
Structure of the Read-command
ON
POWER
OFF (Sleep)
HDMI
DVI-D
D-SUB
Input
OPTION*
VIDEO
YPbPr
S-VIDEO
Around the main
Internal
board
temperature
Around the power
supply
* OPTION can be used when an extension module is mounted on the option slot.
NOTE:
The monitor will acknowledge the power-on/off command issued from the OPS-compliant computer, however, it will not execute
the command. This is not a malfunction. For automatic operation, use SCHEDULE in the CONFIGURATION2 menu of the OSD
screen function.
When you connect the monitor and the computer using a LAN hub and a LAN cable (see page 25) and then confi gure the network
settings using LAN SETTING in the CONFIGURATION2 menu of the OSD screen function, you can remote-control the monitor using
the same commands as those for RS-232C.
1. Setting procedure
(1) Set the following network parameters using the OSD menu. (See page 49.)
• DHCP client ON/OFF, IP address, subnet mask and default gateway
(2) Set the IP address described above and the port number (63007 or 3007) using the application program of your computer to
perform the socket communication.
(3) Send the same control command as that for RS-232C via TCP/IP socket communication.
(4) Check the return command sent from the monitor. When it is received successfully, the setting is completed.
All manuals and user guides at all-guides.com
Return command from monitor to
computer
30 30 76 50 31 0D '0''0''v''P''1'[enter]
ASCII
Function
vP
vP
vI
vI
vI
vI
vI
vI
vI
Resolution
tc1
1˚C
Resolution
tc2
1˚C

LAN Remote control

English-40
Description of command
Sending a command for checking the
power status
Monitor is powered-on.
Data (Receive)
Function
1
76 50
0
76 50
r1
76 49
r2
76 49
r3
76 49
r5
76 49
v1
76 49
v2
76 49
v3
76 49
(ex.) +25
74 63 31
(ex.) +31
74 63 32
Carry out as necessary
HEX
Data (Receive)
31
30
72 31
72 32
72 33
72 35
76 31
76 32
76 33
2B 20 32 35
2B 20 33 31

Werbung

Inhaltsverzeichnis