Mounting the Electric Actuator
GB
DE
NL
FR
8
Ulow E2V • 2022-04-01
The electric actuator must
be mounted on the LEFT side
of the valve body, which is
centrally located on the lower
edge of the radiator. First
connect the cable and then
mount the electric actuator
on the valve body.
Make sure that the cable
always is located BEHIND
the pipe.
Then connect the cable to the
electric actuator.
Then turn the union nut (M
30 x 1.5 mm) onto the valve
by hand.
Attention: The flat side of the
electric actuator must face
backwards or upwards. If you
turn the flat side downwards,
the cable will come loose.