Overload
Recharging-protection
Overload Discharging
Protection
Communication Failure
between the Main Board
and BMS
Light stays on
Communication Failure
between the Main Board
and AC
Inverter Output Overload
Inverter High-Temperature
Protection
Inverter Low-Temperature
Protection
Fan Blockage
Icon(s): Recharging Time, Battery Exclamation, and
OVERLOAD icons flash together.
What to do: Unplug the charging cables, restart the
RIVER MAX 600, and plug back the charging cables
back in. If the light keeps flashing contact
customer service
Icon(s): Battery Exclamation and OVERLOAD icons
flash together.
What to do: Disconnect all appliances, restart the RIV-
ER MAX, and connect each of your appliances back in.
Note: electrical appliances can only be operated within
the specified power range.
Icon(s): Exclamation icon flashes.
What to do: Restart the RIVER MAX. If the icon
keeps flashing, contact customer service.
customer service
Icon(s): Exclamation icon flashes.
What to do: Restart the device. If the light stays on,
contact
customer service.
Icon(s): AC icon flashes.
What to do: Restart the RIVER MAX 600. If the
icon keeps flashing, contact
customer service.
Icon(s): AC and OVERLOAD icons flash together.
What to do: Wait 10 seconds, turn the AC power off.
Please note that all electrical appliances must be
operated within the specified power range. (For more
information about specific appliance use and the
X-Boost function, go to page 12).
Icon(s): AC and High-Temperature icons flash togeth-
er.
What to do: Let RIVER MAX cool down. Turn the AC
Power off; the unit will automatically recover.
Icon(s): The AC and Low-Temperature icons flash
together.
What to do: Move RIVER MAX to a warmer place and
wait for the inverter to warm up. Turn the AC Power
off; the unit will automatically recover. If it doesn't,
contact
customer service.
Icon(s): Fan icon flashes.
What to do: Turn the RIVER MAX off, carefully clean
the unit, and vacuum around the fan vents on both
ends of the product. Turn the unit on, if then Fan
Blockage icon keeps flashing, contact
customer service