INSTALLATION

Rack mounting

The equalizer is built for 19" racks/483mm. The minimum mounting depth is housing depth plus 100 mm for
plugs and cables. The height is 44 mm only. You can fix the equalizer with four screws M6 in the rack.
When mounting the equalizer into a rack, please make sure that there is a proper air circulation.
Please make sure that there is enough space around the device so that the heated air can be passed on.
The rack should be provided with a cooling fan.

Inputs

A good cable run improves the sound quality remarkably. Input cables should be short and direct, since high
frequencies will be mostly be absorbed if the cables are unnecessarily long. Besides that a longer cable may
lead to humming and noise trouble. If long cable runs are unavoidable, you should use balanced cables.
The inputs of your OMNITRONIC DEQ-231 are equipped with XLR and ¼" jack-sockets.

Outputs

The high damping factor of your equalizer supplies a clear sound reproduction. Unnecessarily long and thin
cables will influence the damping factor and thus the low frequencies in a negative way. In order to
safeguard good sound quality, the damping factor should lie around 50.
The outputs of your OMNITRONIC DEQ-231 are equipped with 6.35 jacks and XLR-connectors.
The occupation of the XLR-plugs is as follows:
PIN 1 = Shield
PIN 2 = Signal +
PIN 3 = Signal -
The occupation of the 6.35 jacks is as follows:
TIP = Signal -
RING = Signal +
SLEEVE = Shield

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
International
L
N
18/22