Important!
AS888 must be installed so it
always can move freely and no
floating particles interrupt the
movement. The electrical wires
must be secured preventing them
from falling down onto the switch.
Check AS88 occasionally during
the season ensuring that deposits
or dirt do not interrupt its opera-
tion. Check regularly that the
electrical wires have not been
damanged.

Electrical specification

Max amps
12V DC – 15A
24V DC – 7.5A
32V DC – 5.6A
At heavy loads a separate relay has
to be used. AS888 may only be
used for low voltages (up to 48V).
Bilge pump control 12 or 24V
Part No.
12V – 34-1224/ US:82044
24V – 34-1225/ US: 82044-24V
The bilge pump
control combined
with automatic
switch AS888 is
an excellent
installation for your boat.
The panel has a 3-position
switch for Off, manual On, and
automatic operation
– the automatic feature operates in
combination with AS888.
Integrated fuse holder and
operating light. Fuses are not
included.
6
Fuse is selected according to the
recommended fuse size of the
connected pump, refer to the pump
manual. The switch is in matt black
finish. Size: 76 x 55 mm, 40 mm
depth.

ELECTRICAL INSTALLATION

See fig. page 15
SPX FLOW Johnson Pump
submersible bilge pump/
Automatic Switch AS888/
Bilge pump control
Always install switch AS888 and
bilge pump control or other swit-
ches or fuses between the positive
(+) terminal of the battery and the
positiv (+) connection of the pump
(brown wire, L100 red wire).
The negative (-) connection (black
wire) of the pump to be connected
directly to the negative (-) terminal
of the battery. Fuse size applies to
pump specification.

Electrical connections

All electrical connections must be
placed above the highest water
level. The wire connections should
be sealed with a marine sealant to
prevent wire corrosion. Insulation
or cable sheathings have to be
removed in such a way that they
end well above the highest bilge
water level.
Waste handling/
material recycling
At the products end of life, please dispose
of the product according to applicable law.
Where applicable, please disassemble the
product and recycle the parts material.
Original instructions