3. Electro-acoustic detection device AHO 200
Application
The electro-acoustic detection device AHO 200 is specifically developed for leak
locating in a pipe installation. However, it also offers a variety of other application
options. For example:
Leak locating on water, compressed air or gas pipes
Damage locating and determination on machine parts and motors (bearing
damage etc)
Damage locating and determination on electrical machines and motors
The functional principle of the electro-acoustic detection device AHO200 is based on
the recording of structure-borne sound vibrations, their amplification by order of
magnitudes, and their conversion into an audible sound.
AHO 200 configuration
Battery replacement: Unscrew cover; Replace battery
Headset connection
Volume control
(2)
On/Off
(9)
(9)
Screw the resonance plate onto the lower part of the
(6)
microphone. Now the microphone can be placed on a
surface. The remote release prevents contact noises
during activation. Now you have a ground microphone
(5)
The test prod is used to listen to the fixtures.
(3)
(7)
(1)
Remote release
(4)
17
Battery replacement
(9V block)
EN