6.

Spare parts and their replacement

6.1.

Replacing filters

Only filter designed for CleanAIR® Basic EVO may be used! Filter must be new, unused and in the original packag-
ing. The expiration date must not be exceeded – it is marked on a sticker on the body of the filter.
Filter replacement:
1. Take off the filter cover
2. Pull the filter from the unit.
3. Check the rubber sealing ring at the input to the unit for possible damage.
4. Put the new filter onto the unit.
5. Put on the filter cover.
It is always recommended to use a pre-filter. It catches larger particles and aerosols, while prolonging the life-time
of the filter significantly.
Install only new filter without any visible damage.
It is forbidden to clean a filter or blow through it in any way!
From the hygiene point of view it is not recommended to use filter for more than 1 month after its first use.
6.2.
Batteries
For technical reasons, batteries are not fully charged when leaving the manufacturer. They are supplied with a <
30% charge. Therefore either fully charge the battery before first use, or expect shorter runtime in the first cycle.
For maximum battery life, follow the storage instructions (see Section 9. "Storage")
Battery replacement
see pictorial annex "How to insert the battery".
1.
Grip the powered respiratory unit firmly. Release the safety lock located on the bottom side of the battery. Pull the
battery out of the unit.
2. Insert the battery into the corresponding place on the unit until the click-in stop locks the battery in the right po-
sition.
Battery charging
Slide the battery out of the unit.
Connect the charger into the 100 - 230 V ~ 50/60 Hz mains. A green light indicates the power is on.
Connect the battery to the charger. Charging is indicated by a red light.
When the red light turns to green, the battery is fully charged.
Charging time is approx. 4 hours.
After charging, disconnect the battery from the charger and the charger from the mains.
It is not recommended to leave the charger connected to the mains when not in use.
Charging starts after connecting the battery using the charger to the power supply. After the battery is fully
charged, the charger switches to maintenance mode to keep the battery fully charged.
Green LED on without battery: power is ON
Green LED with battery: battery is fully charged
The battery charger is for indoor use only. Never charge the battery in potentially explosive atmosphere.
It is forbidden to use the battery charger for other purposes than those determined by the producer.
6
Red LED on: charging in progress
Red LED flashing: error (e.g. short circuit)