Herunterladen Inhalt Inhalt Diese Seite drucken

Emergency Stop; Operation Of The Charging Station; Technical Specifications - Ecotap DC 120 Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

23. OPERATION AND FUNCTIONING OF THE CHARGING STATION
The charging station is operated using a charging card.
The charging card must be registered in the relevant back-office system.
This required registration can also be done during office hours by calling
Ecotap® B.V. Tel. +31 (0)411 745 020. Once registration is complete, the
charging station can be used with any Electric Transport charging card (EV
charging card) or other suitable cards, both mobile and key holder.
23.1 Operation
Take the plug from the holder of the charging station that is suited to your vehicle.
Then insert it in your vehicle. If both CHAdeMO and CCS charging points are available, only
one can be used at a time.
Initiate the start/stop procedure by holding your charging card up to the scanning point.
Firstly the plug is locked onto the vehicle.
The charging station then communicates with the vehicle and the back-office system. Once
all security and payment guidelines have been checked, the maximum permissible charging
current is forwarded. After some time, it can occur that the charging station activates the
cooling systems fitted for this purpose to dissipate the excess heat via the venting duct.
The charging procedure is now activated automatically and the DC charging process can be
followed on the screen. The AC charging process is indicated by a small light.
To stop the charging process, hold your pass up to the scanning point. The charging process
then stops. You can now remove the plug and hang it back up in the available holder.

23.2 Emergency stop

In case of emergency, the emergency stop button must always be used.
When activating the emergency stop button, the charging process is disconnected directly,
both in terms of software and hardware.
After careful inspection, the back-office system concerned will reset the emergency setting.
The emergency stop button will also have to be deactivated on site for this purpose.

24. TECHNICAL SPECIFICATIONS

AC INPUT
Input voltage:
Input frequency:
Power factor:
Connection value:
RCD:
Input under voltage protection:
24. www.ecotap.nl
3 x 400VAC + N ± 10%
50Hz
Rated output load PF ≥ 0.99
Minimal 3 x 180A
(With a lower available capacity, the charger
can be set lower by software)
Type B
255V ±5V
08/11/21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis