Procedure
► Remove any fan and the heat sink.
► Pull the lever in the direction of the arrow (1) and lift it as far as it will go (2).
► Fold up the frame.
► Remove the old processor from the socket (3).
► Insert the new processor in the socket so that the bevelled corner of the processor
matches the coding on the socket (A) with regard to the position (4).
► Push the lever back down until it clicks into place (5).
► Depending on the configuration variant, you must pull a protective foil off the heat sink
or coat the heat sink with heat conducting paste before fitting it.
► Depending on the processor variant, clips may also be supplied for mounting
the heat sink that fix it in place.
A26361-D2721-Z110-1-7419, edition 3
Downloaded from
www.Manualslib.com
2
3
1
The bevelled corner of the processor may be in a different position
from that shown in the illustration.
Please note that, depending on the heat sink used, different heat sink
mounts are required on the mainboard.