Herunterladen Inhalt Inhalt Diese Seite drucken

Ayce PD2500I Gebrauchsanweisung Seite 44

Inverter generator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

USB application
The USB socket (16) should only be used for charging 5VDC Max. 2A mobile or digital
equipment.
CAUTION!
• Be sure the total load is within generator rated output.
• Make sure that the appliance being connected is in good working order, if it begins to
act abnormally or stops suddenly, disconnect it from the generator.
• Any device with contains an inductive load e.g. devices that contain a motor may
require more current on startup.
3. Shutting Down the Generator
- Disconnect all appliances connected to the generator.
- Set the Engine ON/OFF Switch (11) to position "O".
- Close the fuel tap (10)
4. Control panel
Run Indicator LED
• The power indicator LED (green) illuminates when power is available to outputs.
Overload Indicator LED
• If the generator is overloaded or if there is a short in the connected appliance the
overload indicator LED (red) will go ON and current to the connected appliance will be
shut off. The output indicator LED (green) will turn off. The power indicator LED (green)
illuminates when power is available to outputs.
• Substantial overloading that continuously lights the overload indicator light (red) may
damage the generator. Marginal overloading that temporarily lights the overload
indicator LED (red) may shorten the service life of the generator. Stop the engine if the
overload indicator light (red) switches ON and investigate the overload source.
Overload Reset
If the overload switch has tripped and cuts off the power, be sure that all appliances are
in good working order before connecting them to the generator. If an appliance begins to
operate abnormally, becomes sluggish, or stops suddenly, turn "OFF' the generator.
1. Disconnect the appliance and push the engine switch into the off position.
2. Start the generator as described in "Starting the engine" section.
3. Refit the appliance, if the Overload trips again then the equipment / appliance needs to
be checked.
Low Oil Indicator LED
85 | 86
GB