Installation Instructions TULOX 100 + 200
Figure 1
Necessary assembly height 37 mm
Key hole
The ease of movement of the bolt in locking mode must be guaranteed. When using bars, angles
or similar blocking elements attached to the bolt, transverse forces, resp. friction on the lock bolt
must be avoided through construction measures. The lock has been tested with an actuating force
of 2.5 N.
The locking force in actuating direction and transverse to the bolt has been tested with 1 kN. Higher
locking forces must be compensated e.g. by supporting the bolt.
Installation procedure
Version 1
If you wish to route the cable through a separate drill hole into the inside of the secure storage unit,
you need to determine a suitable drilling position which corresponds with the VdS guidelines.
Pay careful attention that the drill hole is not positioned in the proximity of the lock situated behind
it and that the drill hole is later covered by the keypad.
It must be ensured that the connecting cable is not crimped during installation and the insulation is
not damaged (Figure 2).
Steinbach & Vollmann GmbH & Co. KG • 42579 Heiligenhaus