TROUBLES AND REMEDIES
TROUBLES
The appliance is not
Power failure.
Faulty cable or switches
functioning.
Water is coming out from the
Recovery tank is too full.
body of the machine (air
outlet).
Suction power has reduced
Clogged or broken hoses,
noticeably
tubes or accessories.
Recovery tank is too full.
Insufficient adherence to
machine body.
The motor is running fast
Clogged hoses, tubes or
(highpitched noise).
accessories.
Recovery tank is too full.
Water leaking from
Joint seals worn or leaking.
accessories joints.
Accessories not fully
Dirt has deposited in the joints
engaging.
and quick connections.
No steam is coming out and
Boiler not yet under pressure
suction is not working.
(green light off).
Power failure.
Appliance plug is not in the
socket.
CAUSES
REMEDIES
Ensure there is power.
Contact the Service Centre.
Empty the recovery tank and
check the float; clean float as
needed.
Clean hoses, tubes or
accessories or replace them.
Empty the recovery tank.
Check if machine body is
secured to the recovery tank
and check that the clips are
fastened.
Clean hoses, tubes or
accessories.
Empty the recovery tank.
Inspect, clean and lubricate
seals; replace seals if necessary.
Clean and lubricate the joints
and quick connections.
Wait a couple of minutes for
the green light to illuminate. If
the problem is still there, contact
one of our Service Centres.
Check that power is available;
check that the plug is properly
connected to the socket.
Check that the appliance plug
is properly connected to the
socket in the electric panel.
40
TROUBLES
Little drops of water dripping
This condition is normal during
the first minutes of operation;
from the accessories.
condensate will form because
of a difference in temperature
between the accessories and
steam.
No water/detergent is
No water or detergent is in
delivered when the pump
the tank (15)
switches both on the
appliance and on the handle
are pressed..
X
X. Overfilling probes in recovery tank. When the recovery tank is overfilled, the probes (13) will
automatically stop the motor. In this case, you need to restart the appliance.
TROUBLES
Suction is not working.
Recovery tank is full.
CAUSES
REMEDIES
The inconvenience is normally
eliminated after a few minutes
of operation; If the trouble is
still there, clean the boiler.
Add more water or detergent.
CAUSES
REMEDIES
Switch off the appliance via
the appliance switches.
Empty the tank, clean the
probes (X), and allow them to
dry.
If the problem persists, contact
your Service Centre.
41