12. TECHNICAL DATA/TECHNISCHE DATEN
English
Tension/Voltage
Max. Current
Max. Power demand
Rating pressure
Max. Operating Pressure
Max water temperature
Input connector
Output connector
Protection-grade
13. ELECTRICAL INSTALLATION /ELEKTRISCHER ANSCHLUSS-PLAN UND INSTALLATIONSSCHEMA
1
2
3
6
Imprint/Impressum
Deutsch
Betriebsspannung
Max. Nennstrom
Max Anschlussleistung
Einschaltdruck
Max. Betriebsdruck
Max. Wassertemperatur
Anschlüsse Eingang
Anschlüsse Ausgang
Schutzart
1. Power/Netz
2. Power/Netz
3. Power/Netz
4. Pump/Pumpe blue/blau (Null)
5. Pump/Pumpe brown/braun (Phase)
6. Pump/Pumpe green-yellow/grün-gelb (Erde)
4
The device is normally connected as shown in figure. Pumps can be operated on
5
the device with higher performance, with a current consumption over 10A, and even
three-phase pumps. In this case, the connection means of a suitable circuit protec-
tion is provided (more information can be found on our Internet site.
Das Gerät wird im Normalfall gemäß Abbildung angeschlossen. An dem Gerät kön-
nen Pumpen mit höheren Leistungen, mit einer Stromaufnahme über 10A und sogar
Drehstrompumpen betrieben werden. In diesem Fall erfolgt der Anschluß mittels ge-
eignetem Schaltschutz (weitere Informationen finden sie auf unserer Internet-Seite.
1A-AZ-AC5-V / 1A-AZ-AC5-U
110-230 VAC ± 10% 50/60 Hz
12A
1,1 kW
1,5 bar
10 bar
55°C
2,54 cm (1")
2,54 cm (1")
IP 65
blue/blau (Null)
brown/braun (Phase)
green-yellow/grün-gelb (Erde)
1A Profi Handels GmbH
www.profi-pumpe.de
Email: info@1a-profi-handel.de
Tel.: (+49) 0611-9 45 87 76-0