1. Release the two setting screws
2. Position the antenna as required.
3. First tighten the setting screw
The tightening torque is 3.5 Nm.
4. Then tighten the setting screw
torque is 3.5 Nm.
4

Connection

WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning
protection system. Make sure that all conducting systems entering from outdoors
can be protected by a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the
VDE 0182 or IEC 62305 standard.
Suitable lightning protectors are available in the range of accessories of SIMATIC
NET Industrial WLAN:
● Lightning protection element LP798-1N (article number 6GK5798-2LP00-2AA6)
● Lightning protection element LP798-2N (article number 6GK5798-2LP10-2AA6)
Note
We recommend that you use the maintenance-free lightning protector LP798-2N.
Exception: When there is also DC power supplied via the antenna cable.
In this case, only use the lightning protector LP798-1N.
WARNING
Danger due to lightning strikes
Installing one of these lightning protectors between an antenna and a SCALANCE
W device is not adequate protection against a lightning strike. The lightning
protectors listed only work within the framework of a comprehensive lightning
protection concept. If you have questions, ask a qualified specialist company.
C79000-G8974-C320-05, 05/2019