Configuration using Switches

Adjust the DIP and rotary switches according to the table on the
housing.
Sensor type:
Select the connected sensor type using switches DIP1 to DIP3.
Start value:
Adjust the number (00 ... 99) using the "Start" rotary switches.
Adjust the factor using the switches DIP4, DIP5.
To obtain a falling curve, adjust a start value which is higher than the
end value.
End value:
Adjust the number (00 ... 99) using the "End" rotary switches.
Adjust the factor using the DIP6 switch.
Output signals:
Adjust the output signal using the switches DIP7, DIP8.
Note
After completion of configuration you must cover the
switches with the included self-adhesive polyimide tape.
For information on IrDA interface configuration, please refer
to the instruction manual for the Paraly ® SW 111 software
(accessory).
P32100P0/11-
S0003-KTA
ES01
Input
Start
End
DIP S1
1 2 3
4 5
6
Pt 100
x(-10)
x10
°C
5 Out +
Pt 1000
x10
x10+1000
x10+1000
Ni 100
Type K
Type J
Type K
ext.comp.
Type J
ext.comp.
Voltage
x(-10)
x10
mV
x(-1)
x1
x1
x1
IrDA
x10
x10
PROG
DIP 1- 8: ON / Start = End = 0
DATA
DIP 1- 8: OFF / Start = End = 0
Output
DIP S1:
7 8
0 to 20 mA
7
4 to 20 mA
Power
0 to 10 V
0 to 5 V
Power
24 to110 V DC, ± 20% 1.3 W
110 to 230 V AC, ± 10% 2.2 VA
x10
x1
ThermoTrans ®
8
Temperature Transmitter
Power
P32100P0/11-S0003-KTA
Type
No.
7 2540000000
ES01
Operat. temp. 0 to + 55 (65) °C
= on
www.knick.de
Made in Germany
50
Start value (rotary switch)
In + 1
End value (rotary switch)
In + 2
DIP S1 (from left to right: 1-8)
mV
Start
End
In
DIP S1
SIL2
Functional Safety
Type Approved
®
T V
Rheinland